Instruments Flow of Liquids, Insertion Electromagnetic Flow Meter, Insertion Type Flow Meter manufacturer / supplier in China, offering Instruments Insertion Type Magnetic Flow Meter Flow of Liquids, Dn10-1000mm Digital RS485 Modbus Liquid Sewage Slurry Water Electromagnetic Flow Meter, Dn50 3.6V Battery Power Liquid Water Electromagnetic Flow Meter and so on.

Diamond Member Since 2019
Audited Supplier

Instruments Insertion Type Magnetic Flow Meter Flow of Liquids

Min. Order / Reference FOB Price
1 Piece US $350/ Piece
Port: Tianjin, China
Production Capacity: 60000/Year
Payment Terms: L/C, T/T, D/P, Western Union, Paypal, Money Gram
Accuracy: ±0.6-1%
Main Application: Wastewater
Size: DN50-100
Sensor: Plug-in
Application: Environmental Protection
Type: Electromagnetic Flow Meter

You Might Also Like

Loading...

Basic Info

Model NO.
DFE
Measuring Media
Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
SGS
Power Supply
DC24 V/220VAC 50Hz
Nominal Pressure
1.6MPa 2.5MPa 4.0MPa
Output
4-20mA /RS485/ Pulse
Electrode Type
316L
Caliber
Dn6-Dn3000mm
Protection Class
IP65 IP67 IP68
Certificate
Ce/ISO 9001/SGS
Trademark
DF
Transport Package
Wooden Case
Specification
100*35*30cm
Origin
China Kaifeng

instruments insertion type magnetic flow meter flow of liquids

Product details

Instruments Insertion Type Magnetic Flow Meter Flow of Liquids
 

DFLD-YIGD and DFLD-FIGD model insertion type electromagnetic flow meter consists of sensor and converter, which was used for measuring the volume flow of various conductive liquids in the pipe.

 

DFLD-YIGD and DFLD-FIGD model insertion type electromagnetic flow meter is widely used for the conductive liquid flow measurement of municipal water supply and drainage, petroleum, chemical, electric power, water conservancy project and other industries. It also used for measuring corrosive conductive liquids like acid, alkali, sodium and etc.

Instruments Insertion Type Magnetic Flow Meter Flow of Liquids
 

  • Simple and strong structure, no movable parts and long service life.
  • Reliable measurement and strong anti-interference performance.
  • Small size, light weight, easy to install and maintain.
  • Wide measuring range, and it will not be influenced by the changes of temperature, density, pressure, viscosity, conductivity and other parameters.
  • Zero pressure lost.
  • It can be installed and dismounted in NON-STOP water condition, and suitable for old and nonstop water supply pipes.
  • The cost and installation fees will be lower than general electromagnetic flow meter, Specially suitable for large and middle diameter pipes.
  • Advanced processing technology, solid-state encapsulation, anti-vibration, long service life, high accuracy and good stability.
  • Standard current output is 0-10mADC or 4-20mADC and frequency output is 1-5000Hz.
  • Digital communication output: RS232, RS485 and Hart.

 

Pipe DiameterDN200-DN3000mm
Flow Range0.1~10m/s
Precision0.5~10m/s : ±1.5%FS;0.1~0.5m/s: ±2.0%FS
0.1~10m/s : ±2.5%FS(FS refer to 40%-100% full scale flow)
Conductivity>50μs/cm
Straight pipeBefore 5DN, after 3DN
Medium Temperature-20ºC ~+130ºC
Ambient Temperature-20ºC ~ +60ºC
Pressure Resistance1.6Mpa
Protection LevelIP65(Integrated type) IP68(Split type)
Electrode Material316L Stainless Steel
Signal Output4-20mA; RS485; HART Protocol; MODBUS Protocol
Sensor MaterialStainless Steel
Working Principal220VAC, tolerance of 15% or +24 VDC, ripple ≤5%
Power6.5W
Pressure Resistance Level≤1.6Mpa

Instruments Insertion Type Magnetic Flow Meter Flow of Liquids
 

The converter of the DFLD-FIGD  is installed in the instrument room or near the sensor that is easily accessible by user, and is separated by tens to hundreds of meters. The converter can be away from the harsh environment of the site, and it is convenient to check, adjust and parameterize electronic components.The converter can be checked, adjusted and set new parameters remotely without going to the installation site.

Instruments Insertion Type Magnetic Flow Meter Flow of Liquids
 

1. Selection of Installation Environment

  • As far away as possible from the devices with strong magnetic field, such as large electric machine, transformer and etc.
  • Easy to install and maintain.
  • Keep the installation site without strong shaking and ambient temperature should be stable.

2.Selection of Installation Position

  • Ensure the fluid filled in the pipe.
  • Be far away from pump and local resistance parts.
  • Please choose the position that not easy to cause the phase separation during measuring the two phase fluids.
  • Avoid the position of negative pressure in the pipe.
  • Inner diameter and perimeter of measuring tube are easy to measure, and the ovality should be small. 

3.Length of Straight Pipe

  • Please ensure the fluid filled in pipe at installation position.
  • Upstream straight pipe of installation position should be more than 10D, downstream straight pipe should be not less than 5D, D is the nominal diameter of pipe.

4.Flow Control Valve And Adjustment Valve

  • Flow control valve should be installed on the upstream measured pipe of sensor. Flow adjustment valve should be installed on the downstream pipe. Generally, flow control valve should keep full open status.

Instruments Insertion Type Magnetic Flow Meter Flow of Liquids
 


Applications

Instruments Insertion Type Magnetic Flow Meter Flow of Liquids
 


Our Service

Instruments Insertion Type Magnetic Flow Meter Flow of Liquids
 


About us

Instruments Insertion Type Magnetic Flow Meter Flow of Liquids
 


Contact us

Instruments Insertion Type Magnetic Flow Meter Flow of Liquids
 

Send your message to this supplier

*From:
*To:
avatar Miss Lu wang
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now